Skip to main content

ISOLATION CHAMBER

The highest level of security and protection against SARS-COV-2

The Isolation Chamber is composed of a structure with two rooms (a vestibule functioning as the airlock and the patient’s section) and a filtration and ventilation Air Handling Unit. The product allows for secure isolation of patients and medical personnel, and as a result, mitigating the risk of spreading SARS-COV-2.
The Isolation Chamber offers the following functionality:

Negative pressure mode

Helps to prevent entering particles and pathogens from the isolation chamber.

Positive pressure mode

Helps to prevent entering particles and pathogens from the outside into the isolation chamber.
After detaching from the isolation chamber, the Air Handling Unit is able to operate in one of the following modes, depending on the specific scenario:

Air cleaner mode

The AHU works as an air cleaner and is capable of cleaning up to 800 m3 of air per hour.

Air extractor

After attaching a flexible hose to the AHU and running the hose outside of the building, the AHU can be used for venting rooms and corridors after the process of decontamination (by fogging), this mode has the capacity of 300 m3 of air per hour.
THE ISOLATION CHAMBER with a filtration and ventilation air handling unit
for biomedical applications
The Isolation Chamber has been designed to create an isolated, closed space for patients infected with SARS-COV-2 or patients under quarantine. The chamber is designed to be used by medical personnel.

Due to the modular design of the ISOLATION CHAMBER, it is best suited for COVID-dedicated hospitals, large medical centers, nursing homes and other public institutions, which have to create special zones of isolation.

ISOLATION CHAMBER

Lightweight Aluminum Frame



The lightweight and modular design of the frame allows for quick and easy assembly and disassembly of the chamber, without using any tools.

2 rooms: airlock and patient room



The transparent foil enables constant observation of the patient's condition without having to enter the cabin.

Wheel ramp



The ramp allows for easy and comfortable deployment of a patient’s bed, medical equipment and other elements inside.

Utility Sleeves



Chamber walls are equipped with technical openings (for supply of medical equipment, introducing medical gases, etc.). The vestibule has a lock-type technical opening for disposing used Personal Protection Equipment.

Airlock for Small Items



Airlock for small items allows for handing over small objects or a meal into the chamber without having to enter the vestibule.

Enough Space for 3 Persons



During resuscitation, there can be 3 medics inside the cabin at the same time.
Description:
  • The alarm system (visual and audible alarm system) managing the entrance and exit procedure, signals the following conditions:
    • Correct/incorrect level of negative pressure inside chambers.
    • Air fan malfunctions.
    • Replacement of worn out filters.
    • Vestibule (air lock) entrance/exit is possible.
    • Patient's section entrance/exit is possible.
    • CO2 level inside the patient's section exceeded.
  • The transparent foil enables constant observation of the patient's condition without having to enter the cabin.
  • Openings with sleeves interface with the devices of the filtering and ventilation system to ensure ventilation and filtration of the air inside the chamber.
  • The lightweight and modular design of the frame allows for quick and easy assembly and disassembly of the chamber.
  • The frame is made of unified aluminum profiles with hexagonal cross-section.
  • Frame connectors are made of anti-corrosive or painted steel.
  • The chamber has the shape of a closed cube, with the vestibule (air lock) and the patient's section inside.
  • The chamber is suspended on the frame via straps with snap buckles.

filtration and ventilation air handling unit

G4, F7, H14 Filters



The AHU is equipped with a 3-stage filtration system for the air entering the unit and for the air extracted from the unit. The AHU uses G4, F7, H14 filters with 99.995% filtration efficiency.

User Friendly Controls



The AHU controls are extremely user-friendly – in order to turn the device on, just switch on the power and push one button.

Easy Transport – Wheels with Brakes



Despite its weight, the AHU is very mobile thanks to the swivel wheels on bearings with a motion lock mechanism to ensure stability when parked.

Low Noise Level (only 45 dBA)



The AHU chambers have been soundproofed with a special noise dampening material to ensure the highest comfort for both the patient and staff.

Easy Assembly of Airducts and Pipes



The air supply and exhaust ducts of the AHU are made of smooth galvanized pipes with a quick connection system ensuring superior tightness.
Description:
  • The filtration and ventilation Air Handling Unit (AHU) maintains the negative pressure of minimum 10 Pa inside the chamber, filters the air entering the chamber and clears the air extracted from the chamber. It ensures appropriate quantity of fresh air inside the patient's section, manages the entrance and exit procedure and ventilates the chamber after the decontamination process.
  • The AHU is equipped with a 3-stage filtration system for the air entering the unit and for the air extracted from the unit. The AHU uses G4, F7, H14 filters.
  • The AHU chambers have been soundproofed with a special noise dampening material to ensure the highest comfort for both the patient and staff.
  • Despite its weight, the AHU is very mobile thanks to the swivel wheels on bearings with a motion lock mechanism to ensure stability when parked.
  • The air supply and exhaust ducts of the AHU are made of smooth galvanized pipes with a quick connection system ensuring superior tightness.
Product presentation

download

ISOLATION CHAMBER is one of many products in this category. Full product specification and related products in this category are available via the following links.

We provide our clients and customers with fast and efficient service. If you have any questions or concerns regarding our offer, please contact our Customer Service.
This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it.

Contact Us

tel.: +48 62 737 5777
fax: +48 62 737 5708
e-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.
Lubawa S.A. ul. Staroprzygodzka 117, 63-400 Ostrów Wielkopolski, NIP 744-00-04-276, REGON 510349127, KRS 0000065741, Prowadzony przez Sąd Rejonowy Poznań - Nowe Miasto I Wilda W Poznaniu, IX Wydział Gospodarczy Krajowego Rejestru Sądowego, Kapitał zakładowy wynosi 30.054.000 zł i został w całości opłacony, BDO 000010404